Last edited by Kigalkis
Tuesday, October 13, 2020 | History

4 edition of Field measurement and calibration using electro-optical equipment, issues and requirements found in the catalog.

Field measurement and calibration using electro-optical equipment, issues and requirements

Field measurement and calibration using electro-optical equipment, issues and requirements

August 24-25, 1982, San Diego, California [proceedings]

  • 310 Want to read
  • 31 Currently reading

Published by SPIE-the International Society for Optical Engineering in Bellingham, Wash .
Written in English

    Subjects:
  • Electrooptical devices -- Congresses

  • Edition Notes

    Includes bibliographical references and indexes.

    StatementFrederic M. Zweibaum and Henry Register, chairmen/editors ; cosponsored by Eglin Air Force Base.
    GenreCongresses.
    SeriesProceedings of SPIE--the International Society for Optical Engineering -- v. 356
    ContributionsZweibaum, Frederic., Register, Henry., Eglin Air Force Base (Fla.), Society of Photo-optical Instrumentation Engineers.
    The Physical Object
    Paginationvi, 169 p. :
    Number of Pages169
    ID Numbers
    Open LibraryOL19019469M
    ISBN 100892523913
    LC Control Number83061335
    OCLC/WorldCa9712610

    This part of ISO specifies field procedures to be adopted when determining and evaluating the precision (repeatability) of electro-optical distance meters (EDM instruments) and their ancillary equipment when used in building and surveying cturer: Multiple. Distributed through American National Standards Institute.   These are rarely sales pitches for one technology. Because the issues involved in large-scale 3-D measurement are complex, presentations often focus on how multiple 3-D equipment, often from different vendors, can be used to solve unique 3-D measurement problems.

    calibration facility, the science of vicarious calibration has had its first major advancement. An autonomous facility makes continual measurements, without the need to deploy a field team. This simplifies the process, reduces the cost and manpower requirements for a project, and allows an archive of data to be used. The CARSO laboratory has recently built a calibration bench for electro-optical qualification of CCD sensors. For the CCD characterization the following measurements are operative: linearity, quantum efficiency, charge transfer efficiency, photon-transfer curve, dark charge and pixel-to-pixel sensitivity : R. Stalio, A. Bucconi, P. Trampus, F. Visintini, F. De Carlo, A. Antonini.

    Calibration of Upright Cylindrical Tanks Using the Internal Electro-optical Distance Ranging (EODR) Method (ANSI/API MPMS D) 2: X: COPM: Ch. Production Measurement and Allocation Systems: 2: X: COPM: Ch. Measurement of Flow to Flares: 2: X. The Surveyor-General of Victoria Practice Directives, September addresses the requirements regarding calibration of Electro-optical Distance Meter (EDM) instruments. It states that EDM instruments must be calibrated over a certified baseline at intervals not exceeding 12 months, or more frequently if conditions warrant it.


Share this book
You might also like
Green goddesses go east

Green goddesses go east

Mechanical Working and Steel Processing Xxi

Mechanical Working and Steel Processing Xxi

The Sauria (lizards and varanids) of Sri Lanka

The Sauria (lizards and varanids) of Sri Lanka

Vietnam, Cambodia and Laos handbook

Vietnam, Cambodia and Laos handbook

Paul, bishop, servant of theservants of God, together with the fathers on the sacred council, puts on permanent record the decree on the pastoral office of bishops in the church

Paul, bishop, servant of theservants of God, together with the fathers on the sacred council, puts on permanent record the decree on the pastoral office of bishops in the church

Ford Explorer & Mercury Mountaineer automotive repair manual

Ford Explorer & Mercury Mountaineer automotive repair manual

Abstract set theory.

Abstract set theory.

The 2000-2005 Outlook for Fruit in North America and the Caribbean

The 2000-2005 Outlook for Fruit in North America and the Caribbean

The Deryni archives

The Deryni archives

Nothing Twice

Nothing Twice

Curiosities of medical experience.

Curiosities of medical experience.

Weekend in Dinlock.

Weekend in Dinlock.

Taxation of prizes, awards, and scholarships.

Taxation of prizes, awards, and scholarships.

Fourth interim report of the commercial fish-technical evaluation study

Fourth interim report of the commercial fish-technical evaluation study

Field measurement and calibration using electro-optical equipment, issues and requirements Download PDF EPUB FB2

Add tags for "Field measurement and calibration using electro-optical equipment, issues and requirements: August, San Diego, California [proceedings]". Be. Get this from a library. Field measurement and calibration using electrooptical equipment: issues and requirements, August, San Diego, California.

[Frederic Zweibaum; Henry Register; Eglin Air Force Base (Fla.); Society of Photo-optical Instrumentation Engineers.;]. Field Measurement and Calibration Using Electro-Optical Equipment (Proceedings of Spie) on *FREE* shipping on qualifying offers. Field Measurement and Calibration Using Electro-Optical Equipment (Proceedings of Spie).

depend on the precise task. Use of eyechart-like calibration targets - is common in DoD applications. EO/IR sensors divided into scanning sensors, which usemay be a limited number of detectors toscan across the scene, and staring sensors, which use large numbers of detectors in rectangular arrays.

Non-Imaging EO/IR Systems. CONFERENCE PROCEEDINGS Papers Presentations Journals. Advanced Photonics Journal of Applied Remote Sensing. About Electro Optical Industries. Electro Optical Industries, is a global provider of photonics equipment for wide area surveillance, industrial thermography, and visible/infrared test and measurement applications, with 3 Field measurement and calibration using electro-optical equipment lines: the SPYNEL series, day&night degree cameras, provide unprecedented situational awareness on land or at sea.

platforms and equipment using highly precise measurements across the physical/dimensional, radiological, electrical, electronic, and electro–optical spectrums.

Because of this, TMDE is recognized as a unique commodity of equipment that requires centralized acquisition and support considerations.

Size: 1MB. The electro optical distance ranging (EODR) method offers state-of-the-art technology for internal calibration of vertical, cylindrical tanks.

The method provides a safe, accurate alternative to. An accurate measurement of highly reflective surfaces using a spectrophotometer is challenging for many of the same reasons outlined above for AR transmission measurements.

Small changes in measured signal at the detector between the reference and measurement lead to significant errors in measured performance. This standard describes measurement and calculation procedures for determining the diameters of upright cylindrical tanks by taking vertical offset measurements externally using Electro-optical Distance Ranging (EODR) equipment rather than conventional ORLM plummet/ trolley equipment.

This standard is an alternate standard to API MPMS Ch. B File Size: KB. This wider definition is commonly used by practitioners in the field to cover all forms of manipulation, including creation, measurement, calculation, modeling, and simulation of optical flux.

The focus of this book is not on radiometric measurement but on the analysis and modeling of measured data, and the design of electro-optical systems.

A 'read' is counted each time someone views a publication summary (such as the title, abstract, and list of authors), clicks on a figure, or views or downloads the full-text.

A common motivation for using optical techniques to measure voltages and currents is the need for electrical isolation of the measurement system from the system which is being measured. Ground current effects can be minimized because optical coupling eliminates the wires connecting the two by: 6.

Using the latest laser theodolite technology for tank calibration, engineers and technicians are equipped with state-of-the-art measuring use of EODR (Electro Optical Distance Ranging) laser scanning offers a quicker, safer, low impact solution for strapping storage vessels.

On this basis, the improvement work of applying IOESs to intense E-field measurement is introduced. Section 3 illustrates the typical applications of intense E-field measurement using IOESs. The measurement of the DC field, power frequency AC field, μs-order transient field, and ns-order transient field are demonstrated for high-voltage Cited by: Calibration of Strapdown Magnetometers in Magnetic Field Domain by onboard electric equipment.

To this aim, calibration data must be collected in. 2) Ground test equipment. 3) Calibration equipment and facilities. 4) Pre-flight test program and objectives.

5) Flight data reduction algorithms. 6) Test data reduction algorithms. Justification Radiometric accuracies of 3% or better require early identification of critical instrument parameters, of available primary and transfer standards ii.

This part of ISO specifies field procedures to be adopted when determining and evaluating the precision (repeatability) of electro-optical distance meters (EDM instruments) and their ancillary equipment when used in building and surveying measurements.

This part of ISO is applicable to reflector-type EDM instruments only and is not designed to determine the.

Abstract. Distance meters featuring visible light or near infrared (NIR) radiation as carrier waves are called electro-optical EDM instruments. These carrier waves follow the laws of geometrical optics; normal telescopes are used for transmitting and receiving the : J.

Rüeger. However, when the electric field is modulated, the induced optical axis rotates, the machining process is required to be high, the voltage of the crystal half-wave is high, and the sensitivity of the measured electric field is not as high as the LN crystal, which is suitable for the measurement of a high-voltage electric field.

(2) LN crystal Author: Chi Zhang, Yu Cui, Jianfei Ji, Xingxin Guo, Tuo Luo, Xinyue Gong. Under ideal conditions, the most advanced GPS equipment can only get down to 5mm accuracy, with real world results probably being closer to 10mm.

It is true that GPS is often the faster and easier to use technology in the field when compared to electro-optical solutions, and with comparable accuracy levels has displaced traditional methods.SDL has a long history of performing electro-optical testing, calibration, and characterization of diverse sensor systems and associated test equipment for both in-house and customer programs.

Areas of Emphasis. System Calibration Planning. End-to-End Sensor Testing & Calibration. Focal Plane Characterization. Stray Light.The uncertainty can be due to the setup (e.g., field measurement probe calibration uncertainty), or due to the animals (e.g., anatomical model representation), growth rate, and update frequency of the average weight of the different rodent groups and the weight distribution with each by: 7.